This is the latest recevied telemetry packets stored in our database for station/object SV0SYH-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1782031478 | 156 Count | 938 Count | 140 Count | 4.06 VDC | 0 VDC |
| 1782027868 | 121 Count | 753 Count | 107 Count | 4.06 VDC | 0 VDC |
| 1782020670 | 77 Count | 490 Count | 67 Count | 4.06 VDC | 0 VDC |
| 1782018853 | 65 Count | 403 Count | 56 Count | 4.06 VDC | 0 VDC |
| 1782017082 | 54 Count | 328 Count | 50 Count | 4.06 VDC | 0 VDC |
| 1782015280 | 45 Count | 271 Count | 42 Count | 4.06 VDC | 0 VDC |
| 1782011673 | 23 Count | 134 Count | 22 Count | 4.04 VDC | 0 VDC |
| 1782004461 | 128 Count | 901 Count | 113 Count | 4.06 VDC | 0 VDC |
| 1782000855 | 104 Count | 770 Count | 91 Count | 4.07 VDC | 0 VDC |
| 1781999052 | 91 Count | 707 Count | 79 Count | 4.07 VDC | 0 VDC |
| 1781979252 | 91 Count | 882 Count | 79 Count | 4.11 VDC | 0 VDC |
| 1781977454 | 83 Count | 818 Count | 72 Count | 4.11 VDC | 0 VDC |
| 1781973885 | 61 Count | 622 Count | 56 Count | 4.11 VDC | 0 VDC |
| 1781972075 | 52 Count | 552 Count | 48 Count | 4.12 VDC | 0 VDC |
| 1781957650 | 86 Count | 801 Count | 74 Count | 4.13 VDC | 0 VDC |
| 1781955854 | 73 Count | 728 Count | 62 Count | 4.12 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)